Determining an Observation’s Orientation

When determination of position angles from HST images is critical, or in other cases when accurate knowledge of HST orientation is important, users are advised to perform the following check.

The science header keyword ORIENTAT is populated by adding the angle between the HST V3 axis and the detector Y axis to what we will call the "commanded roll" (North to V3 through East). The V3-detY angles that were relevant at a given observation's epoch are given as a header keyword (beta_2) in the Observation Log files (aka jitter files). The GO can obtain the observation logs by requesting them from the archive.

The commanded roll can be determined by subtracting the beta_2 from ORIENTAT. If a particular orientation was specified in the phase II (via ORIENT) this will be equivalent to the commanded roll +180 by definition. Note that the science header keyword PA_V3 is not equivalent to the commanded roll because PA_V3 is defined at the V1 axis while the commanded roll and ORIENTAT are defined at the particular SI aperture reference point. The science header keyword PA_APER is the commanded roll plus the angle from V3 to a slit's Y axis, which may be slightly different than the detector's Y axis. For long slit observations, this PA_APER can be of importance, describing the position angle of the slit. But as mentioned these keywords are all derived from some assumed "commanded roll", begging the question...

So how close is the actual orientation to the commanded?

Normally, in the absence of pointing or science header anomalies, the actual initial roll achieved for a given HST observation is within ~0.003 degrees of the commanded value. For context, the angle error that will put an object out of the 52X0.1 STIS slit is 0.1 degrees (assuming an object centered at the slit center and the other object at the end of the slit).

The GO should check the "_jif" jitter file's header keyword ROLL_AVG. This is the angle from North to V3 measured at the aperture reference calculated by the guidestars' locations in the FGSs. They should then check this value against the c0h science header by performing the subtraction discussed in the first paragraph to get the "commanded roll" assumed in the science data. The commanded roll and the jitter file's ROLL_AVG should agree to within 0.05 degrees, usually better than 0.02deg. If this is the case, then the user should trust the science header's roll, which when not affected by gross errors, is usually closer to what was actually executed than the jitter file reports*. See archived roll discussion. The commanded roll is used by the science data processing to derive and populate the ORIENTAT, PA_APER and PA_V3 keywords, as well as other keywords utilized by many STSDAS image measurement tasks.

If the two sources differ by ~0.05 deg or more, then the GO should contact us.

After some checks, we will usually be able to recommend a course of action:

  1. Relying on the jitter file's measured roll if a problem is found either with the science header population or with the execution of the commanded roll.
  2. Dismissing the jitter file's roll calculation due to problems with it* and verifying the science header roll.


See our archived Pointing Calculations and Sources of Error discussion for more details of orientation, pointing, and the jitter files.

Also, for the current values of the aperture parameters, see the FoV Geometry page.
 

 

Pre-footer

HST Help Desk 

Please contact the HST Help Desk with any questions.